LudgerClean procainamide plate
Each pack contains one hydrophilic interaction polypropylene 96-well plate. For removal of excess procainamide label after procainamide labelling of glycans.
For use in a vacuum manifold system (e.g. Ludger LV system).
The LC-PROC-96 plate is a 96-well membrane-bottom plate containing a specialized glycan binding membrane. This product is designed for use with both the vacuum manifold that can be purchased from Ludger and with other popular vacuum manifold systems. Excess procainamide label passes through the membrane whilst glycans are bound to the membrane allowing separation of these two components.
Plate appearance: The membrane in the wells of the plate appears off-white which gives the appearance of a greyish residue on the membrane. The residue seen and the appearance of the plate are a normal occurrence and do not affect the plate's performance.
View product documentation
Product Specifications
Applications: Post-procainamide Cleanup . For removal of excess procainamide label after procainamide labeling of glycans. This clean-up plate is used where excess procainamide interferes with subsequent sample analysis.
Description: The LC-PROC-96 plate is a 96 well membrane-bottom plate containing a specialized glycan binding membrane. This product is designed for use with both the vacuum manifold that can be purchased from Ludger or with other popular vacuum manifold systems. Excess procainamide label passes through the membrane whilst glycans are bound to the membrane allowing separation of these two components.
Plate appearance: The membrane in the wells of the plate appears off-white which gives the appearance of a greyish residue on the membrane. The residue seen and the appearance of the plate are a normal occurrence and do not affect the plate performance.
Number of Samples: Sufficient for up to 96 samples.
Volume of Sample: Up to 350 μL per well.
Suitable Samples: Procainamide labeled glycans. Typical samples would be procainamide labelled glycans from up to 100 μg of IgG glycoprotein.
Storage: Store at room temperature. Protect from sources of heat, light, and moisture. When stored correctly, the plate should be stable for 36 months from date of purchase.
Shipping: The product should be shipped at ambient temperature. For research use only. Not for human or drug use
Kit Contents
The kit contains the following materials:
Cat. # | Item | Quantity |
LC-PROC-96 | LudgerClean 96 well procainamide labelled glycan clean-up plate |
1 |
Additional Reagents and Equipment Required
For a full list of vacuum manifold accessories see the Ludger-Velocity-Guide available from our website or upon request.
• Pure water: resistivity above 18 M-cm, particle free (>0.22 μm), TOC <10 ppb
• 70 % ethanol solution
• Acetonitrile (HPLC grade)
• Vacuum manifold suitable for 96 well format SPE plates (cat. no. LC-VAC-MANIFOLD Kit)
• Vacuum trap (cat. No. LC-VACUUM-TRAP-KIT)
• 2 mL collection plate for collecting glycans (cat. No. LP-COLLPLATE-2ML-96).
• Collection plate lid (optional) (cat. No. LP-COLLPLATE-LID-96).
Safety and Handling
• Ensure that any glass, plasticware or solvents used with this item are free of environmental carbohydrates. Use powder-free gloves for all sample handling procedures and avoid contamination with environmental carbohydrate.
• Once used, the plate should be discarded according to local safety rules.